Plasterboard sheet calculator

Work out how many sheets a room or wall needs, in the sizes NZ merchants actually stock, before you order. Sheets, screws and waste, live as you type.

This free NZ plasterboard calculator (GIB is the brand most Kiwis say) works out how many sheets you need for a whole room or a single wall, using the standard sheet sizes sold here: 1200mm wide in lengths from 2.4m to 3.6m, plus the 1350mm wide boards for higher walls. It deducts doors and windows, adds waste, and estimates your screw count. Below the tool there is a plain guide on sheet layout, wet-area board and levels of finish.

WEB GRENADE · PLASTERBOARD ESTIMATOR

Length times height. For several walls, add the areas together and subtract any doors or windows yourself in this mode.

Fine-tune the assumptions

Door default is a standard NZ interior door opening (about 1.98 x 0.81m). There is no standard NZ window size, so edit that one to suit yours. The screw rate assumes studs at 600mm centres with screws at roughly 200mm on sheet ends and 300mm elsewhere.

Sheets to order
17sheets
covers 42.6m² plus 10% waste, in 2.4 x 1.2m sheets
Area to line42.6 m²
Screws (approx)500
Order everything in one hit so it all comes from the same batch.
Don't forget
  • Stopping compound and paper jointing tape
  • External corner beads for outside corners
  • Wet-area board for bathrooms and laundries
  • Glue (daubs on studs) as well as screws

Suppliers do not publish reliable per-m² coverage for compound or tape, so buy those on your merchant's advice for your sheet count.

Estimates for planning only. Sheet sizes per the GIB and Elephant Plasterboard published ranges; always confirm what your local merchant stocks before ordering. Sources listed below.
The plain guide
01

How to use this plasterboard calculator

Pick a mode, punch in your measurements, and the sheet count updates as you type. Whole room takes the room's length, width and stud height, lets you toggle walls and ceiling, and deducts your doors and windows automatically. Single wall just takes an area in square metres, which suits a garage wall, a hallway or a patch job where you have already done the sums.

Then choose a sheet size. The count assumes you will use the offcuts sensibly, which is what the waste margin is for. Ten percent suits most rooms. Bump it up for rooms with lots of angles, wardrobes and bulkheads, and down toward five for one big plain wall.

02

Sheet layout: fewer joints beats less offcut

6.0mlongest standard sheet sold in nz

The instinct is to pick the sheet size that wastes the least board. Resist it. Every joint you create has to be taped, stopped three times and sanded, and every joint is a place the eye can catch a flaw later. Board is cheap. Stopping is the expensive, skilled, slow part. So the pros pick the layout with the fewest joints, not the least offcut.

In practice that means the longest sheets you can carry and get into the room. Standard sheets here are 1200mm wide in lengths from 2.4m right up to 6m. On a 4m wall, one 3.6m sheet plus a 400mm piece beats two shorter sheets, because the single joint lands in one place instead of two.

On walls higher than 2.4m, look at the 1350mm wide sheets fixed horizontally. Two courses of 1350 covers a 2.7m stud exactly, with one horizontal joint at a comfortable working height instead of vertical joints every 1200.

03

Ceilings first, always

Line the ceiling before the walls. The wall sheets then push up against the ceiling sheets and support their edges, which stiffens the whole junction and hides the ceiling sheet's cut edge inside the corner. Do it the other way round and you are fighting gravity while trying to leave a tidy edge on show.

Ceiling sheets are the heavy, awkward ones, so this is also the moment to be honest about help. Two people and a couple of T-props (or a hired panel lifter) make a ceiling a morning's work. One person and pride make it a chiropractor's invoice.

04

Wet-area board: where and why

Bathrooms, laundries and toilets get wet-area board. GIB Aqualine is the one most merchants reach for, and Elephant AquaSmart is the equivalent. The core is treated to resist moisture, so an ordinary splash or a steamy mirror does not slowly turn the lining to porridge.

Two things people get wrong. First, wet-area board is not waterproofing. Behind a shower or over a bath, tiles need a proper waterproofing membrane applied over the board. The board is the substrate, the membrane is the raincoat. Second, standard board in a bathroom is not automatically illegal, but wet-area board is cheap insurance in the one room guaranteed to test it, so treat it as the default.

05

Levels of finish, in one plain paragraph

L4the standard nz finish level

NZ finishing is graded under the joint Australia/NZ standard for gypsum linings (AS/NZS 2589), and the two levels you will actually hear quoted are Level 4 and Level 5. Level 4 is the default: joints, internal angles and screw heads taped and stopped with three coats, everything sanded flat, bare paper in between. Level 5 adds a thin skim coat of compound across the entire surface. You specify Level 5 where a wall gets raking light from a big window or wall wash lighting, or where the paint is semi-gloss, because those are the conditions that make Level 4 joints ghost through an otherwise perfect paint job. If a stopper quotes you "F4" or "F5" they mean the same two levels.

06

DIY the hanging, think hard about the stopping

Hanging board is honest DIY territory: measure, cut with a knife and a snap, glue and screw. Screws go in until the head sits just below the surface without tearing the paper, roughly 200mm apart on sheet ends and 300mm elsewhere along the studs. Get a screw gun with a depth clutch and it is hard to get wrong.

Stopping is a different sport. Three coats, each wider than the last, feathered to nothing, then sanded under a raking light. A good stopper makes a wall disappear; a first-timer makes every joint a speed bump you will see for the next twenty years, because paint hides nothing. The honest play for most owner-builders: hang the board yourself, pay a professional stopper for the finish. You save the labour that is easy and buy the labour that is not.

Sources: GIB Standard and GIB Wideline published sheet ranges (1200mm and 1350mm widths, lengths 2.4m to 6m), Elephant Plasterboard product range, GIB Aqualine (wet areas), GIB on Level 4 and 5 finishes (AS/NZS 2589). Screw spacing and deduction defaults are editable assumptions, not gospel; follow the GIB Site Guide for your specific board and framing. Guide only, not building advice.

Quick answers
How many sheets of plasterboard do I need for a room?

Measure each wall (length times stud height), add the ceiling if you are lining it, subtract doors and windows, add about 10 percent for offcuts, then divide by the sheet area. A 4 x 3m room with 2.4m studs, lined walls and ceiling, one door and one window comes to roughly 17 standard 2.4 x 1.2m sheets. This calculator does all of that live as you type.

What size plasterboard sheets should I use?

The longest sheets you can safely handle and get into the room. Standard NZ sheets are 1200mm wide in lengths from 2.4m up to 6m, and 1350mm wide sheets exist for horizontal fixing on higher walls. Fewer, longer sheets mean fewer joints, and joints are where the labour and the visible flaws live. A little more offcut waste is almost always worth fewer joints.

Do I need wet-area plasterboard in a bathroom?

Use a wet-area board (GIB Aqualine is the common one, Elephant AquaSmart is the equivalent) in bathrooms, laundries and toilets. It has a moisture-resistant core. Behind showers and baths, tiles still need a proper waterproofing membrane over the board. The board resists moisture, it is not a waterproofing system on its own.

What is the difference between a Level 4 and Level 5 finish?

Level 4 is the standard NZ finish: joints, corners and screw heads are taped and stopped with three coats, and the rest of the board is left as paper. Level 5 adds a thin skim of compound over the entire surface. You pay for Level 5 where the light rakes along a wall or you are using semi-gloss paint, because that is where Level 4 joints can ghost through.